title: "Evgenii Konkin (@evgeniikonkin) | Hashnode"
description: "Civil & Mechanical Engineer · Building engineering calculators at calcengineer.com. Read the latest articles by Evgenii Konkin on Hashnode."
url: "https://hashnode.com/@evgeniikonkin"
---

@evgeniikonkin

# Evgenii Konkin

@evgeniikonkin · Los Angeles, USA · Joined April 2026

Civil & Mechanical Engineer · Building engineering calculators at calcengineer.com

[Website](https://calcengineer.com/)

### [Heat Pump Delta T Has No Single "Normal": Build an Expected-ΔT Check From Two Rating Points Subtitle: A 25–35°F rule of thumb fails on cold mornings](https://calcengineer.hashnode.dev/heat-pump-delta-t-has-no-single-normal-build-an-expected-t-check-from-two-rating-points-subtitle-a-25-35-f-rule-of-thumb-fails-on-cold-mornings?utm_source=hashnode&utm_medium=feed)

Every HVAC troubleshooting chart has a line like this: heat pump, heating mode, normal ΔT 25–35°F. It's a useful rule on a mild day. On a 17°F morning it will tell you that a perfectly healthy system

6 min read · [calcengineer.hashnode.dev](https://calcengineer.hashnode.dev/heat-pump-delta-t-has-no-single-normal-build-an-expected-t-check-from-two-rating-points-subtitle-a-25-35-f-rule-of-thumb-fails-on-cold-mornings?utm_source=hashnode&utm_medium=feed)

[2d ago](https://hashnode.com/posts/heat-pump-delta-t-has-no-single-normal-build-an-expected-t-check-from-two-rating-points-subtitle-a-25-35-f-rule-of-thumb-fails-on-cold-mornings/6af7f045a98504d62cd46eb5)

### [Dew Point Uncertainty: When a Positive Surface Margin Spans Zero](https://calcengineer.hashnode.dev/dew-point-uncertainty-when-a-positive-surface-margin-spans-zero?utm_source=hashnode&utm_medium=feed)

A calculated dew point of 11.09°C looks precise. If the measured surface is at 12.00°C, subtracting the two suggests a comfortable positive margin. But the digits describe the calculation; they do not

8 min read · [calcengineer.hashnode.dev](https://calcengineer.hashnode.dev/dew-point-uncertainty-when-a-positive-surface-margin-spans-zero?utm_source=hashnode&utm_medium=feed)

[4d ago](https://hashnode.com/posts/dew-point-uncertainty-when-a-positive-surface-margin-spans-zero/6af54ebb8720c34084263941)

### [Data Center Power Math: Converting kVA to kW for Server Rack Planning](https://calcengineer.hashnode.dev/data-center-power-math-converting-kva-to-kw-for-server-rack-planning?utm_source=hashnode&utm_medium=feed)

Tags: electrical-engineering, data-center, power-systems, engineering, infrastructure Planning power capacity for a data center means dealing with two numbers that look similar but aren't: kVA and kW

3 min read · [calcengineer.hashnode.dev](https://calcengineer.hashnode.dev/data-center-power-math-converting-kva-to-kw-for-server-rack-planning?utm_source=hashnode&utm_medium=feed)

[6d ago](https://hashnode.com/posts/data-center-power-math-converting-kva-to-kw-for-server-rack-planning/6af2af16517f5b9070c41149)

### [Your Ducts Are the Right Size. But 25% of the Air Never Reaches the Room.](https://calcengineer.hashnode.dev/your-ducts-are-the-right-size-but-25-of-the-air-never-reaches-the-room?utm_source=hashnode&utm_medium=feed)

Tags: HVAC, Mechanical Engineering, Ductwork, Energy Efficiency A homeowner complains that the master bedroom is always warm. The HVAC tech checks the system: airflow at the air handler is 1,200 CFM

5 min read · [calcengineer.hashnode.dev](https://calcengineer.hashnode.dev/your-ducts-are-the-right-size-but-25-of-the-air-never-reaches-the-room?utm_source=hashnode&utm_medium=feed)

[Nov 7](https://hashnode.com/posts/your-ducts-are-the-right-size-but-25-of-the-air-never-reaches-the-room/6aeeb90d0cf7a4a373eff174)

### [Wet-Bulb Temperature: The Number That Determines Heat Stress and Cooling Tower Performance — Not the Thermometer.](https://calcengineer.hashnode.dev/wet-bulb-temperature-the-number-that-determines-heat-stress-and-cooling-tower-performance-not-the-thermometer?utm_source=hashnode&utm_medium=feed)

Tags: HVAC, Mechanical Engineering, Thermodynamics, Building Science A construction site manager checks the weather app. It says 95F. He decides it is hot but workable — his crews have handled 95F be

5 min read · [calcengineer.hashnode.dev](https://calcengineer.hashnode.dev/wet-bulb-temperature-the-number-that-determines-heat-stress-and-cooling-tower-performance-not-the-thermometer?utm_source=hashnode&utm_medium=feed)

[Nov 3](https://hashnode.com/posts/wet-bulb-temperature-the-number-that-determines-heat-stress-and-cooling-tower-performance-not-the-thermometer/6ae9687d5fa67349547e9652)