title: "Pavel Barysenka (@pavelbarysenka) | Hashnode"
description: "Pavel Barysenka (@pavelbarysenka) writes on Hashnode. Read their latest articles and follow their work."
url: "https://hashnode.com/@pavelbarysenka"
---

@pavelbarysenka

# Pavel Barysenka

@pavelbarysenka · Valencia, Spain · Joined October 2026

### [Sag Calculation: How Low Can the Tension Go?](https://pavelbarysenka.hashnode.dev/sag-calculation-how-low-can-the-tension-go?utm_source=hashnode&utm_medium=feed)

A wire pulled into place cannot hang deeper than W/H = 2.4. Below that tension the sag formulas still compute, but they describe a wire nobody can install

14 min read · [pavelbarysenka.hashnode.dev](https://pavelbarysenka.hashnode.dev/sag-calculation-how-low-can-the-tension-go?utm_source=hashnode&utm_medium=feed)

[Oct 27](https://hashnode.com/posts/sag-calculation-how-low-can-the-tension-go/6ae11958fddb380ec688a7c0)

### [Sag Calculation: Segment Equilibrium Method](https://pavelbarysenka.hashnode.dev/sag-calculation-segment-equilibrium-method?utm_source=hashnode&utm_medium=feed)

Point loads and inclined spans solved with hinged segments and three passes in Excel, no VBA.

12 min read · [pavelbarysenka.hashnode.dev](https://pavelbarysenka.hashnode.dev/sag-calculation-segment-equilibrium-method?utm_source=hashnode&utm_medium=feed)

[Oct 24](https://hashnode.com/posts/sag-calculation-segment-equilibrium-method/6add15567629ae58ded114e7)

### [Sag Calculation: Parabola vs. Hyperbolic](https://pavelbarysenka.hashnode.dev/sag-calculation-parabola-vs-hyperbolic?utm_source=hashnode&utm_medium=feed)

Two sag curves that differ in one assumption, dx or dL. Where the parabola is enough, where inclined spans break it, and the exact curve in Excel

12 min read · [pavelbarysenka.hashnode.dev](https://pavelbarysenka.hashnode.dev/sag-calculation-parabola-vs-hyperbolic?utm_source=hashnode&utm_medium=feed)

[Jan 13](https://hashnode.com/posts/sag-calculation-parabola-vs-hyperbolic/6ae728953c6a068f934445ad)

### [Stranded Conductors: Unseen Stiffness](https://pavelbarysenka.hashnode.dev/stranded-conductors-unseen-stiffness?utm_source=hashnode&utm_medium=feed)

How the lay angle of the wires lowers the stiffness of a stranded conductor, with a geometry model checked against IEC 61597 and EN 50182

17 min read · [pavelbarysenka.hashnode.dev](https://pavelbarysenka.hashnode.dev/stranded-conductors-unseen-stiffness?utm_source=hashnode&utm_medium=feed)

[Jul 29, 2025](https://hashnode.com/posts/stranded-conductors-unseen-stiffness/6ae7590df7c8736ef4f8c071)

### [Composite Conductors: Core Ideas and Unseen Challenges](https://pavelbarysenka.hashnode.dev/composite-conductors-core-ideas-and-unseen-challenges?utm_source=hashnode&utm_medium=feed)

How to replace an aluminium-steel conductor with an equivalent homogeneous wire, and why the standard tables give a modulus of elasticity up to 22% below the calculated one

13 min read · [pavelbarysenka.hashnode.dev](https://pavelbarysenka.hashnode.dev/composite-conductors-core-ideas-and-unseen-challenges?utm_source=hashnode&utm_medium=feed)

[May 27, 2025](https://hashnode.com/posts/composite-conductors-core-ideas-and-unseen-challenges/6ae75215427b8785c7ac39fa)