title: "Comment by Akhila Sharon N. on \"Should you trust an object detector’s confidence?\" | Hashnode"
description: "Really neat findings Oleg. Modern models improving accuracy while regressing on score reliability is a classic trade off. The Platt correction results are impre"
url: "https://hashnode.com/posts/object-detection-confidence-calibration/6ac5a141dd27d808f63b1dd3/comment/6ac78ff44cbe3adc689cfac3"
---

[Discussion](https://hashnode.com/posts/object-detection-confidence-calibration/6ac5a141dd27d808f63b1dd3)

Comment [Should you trust an object detector’s confidence?](https://hashnode.com/posts/object-detection-confidence-calibration/6ac5a141dd27d808f63b1dd3)

[Akhila Sharon N.](https://hashnode.com/@akhila-003)

[Oct 8](https://hashnode.com/posts/object-detection-confidence-calibration/6ac5a141dd27d808f63b1dd3/comment/6ac78ff44cbe3adc689cfac3)

Really neat findings Oleg. Modern models improving accuracy while regressing on score reliability is a classic trade off. The Platt correction results are impressive. Did you notice any major difference in performance between temperature scaling and Platt scaling on rarer classes?

[Oleg Serov](https://hashnode.com/@sirserow)

[Oct 8](https://hashnode.com/posts/object-detection-confidence-calibration/6ac5a141dd27d808f63b1dd3/comment/6ac78ff44cbe3adc689cfac3#reply-6ac7c21c0d393c5f216610b6)

Ahila, thank you for you comment, that's an interesting metric to check! To do this I defined rare classes as the 20 COCO classes with the fewest labeled objects in the calibration split. Together, they had 773 eligible test detections. On this subset the ECE value for Temperature was about 9.89 percentage points, while Platt gave 3.74 (lower is better). So Platt still showed better calibration on the rare classes, although individual class results varied and many had small sample sizes.