Tag

# #datacentercooling

3 posts · 0 followers

[Mahammadasrar Ghanchi](https://hashnode.com/@asrar092) · [Nov 3](https://hashnode.com/posts/data-center-basics-a-beginner-s-guide/6ae9b185bd0a4bf01a597cde)

### [Data Center Basics: A Beginner's Guide](https://mahammadasrar.hashnode.dev/data-center-basics-a-beginner-s-guide?utm_source=hashnode&utm_medium=feed)

What is a data center? A data center is a big, secure building full of computers. These computers run all day and all night, so your apps and websites never go to sleep. Think about your last hour onl

6 min read · [mahammadasrar.hashnode.dev](https://mahammadasrar.hashnode.dev/data-center-basics-a-beginner-s-guide?utm_source=hashnode&utm_medium=feed)

[Evgenii Konkin](https://hashnode.com/@evgeniikonkin) · [Apr 16](https://hashnode.com/posts/the-engineering-math-behind-data-center-cooling-redundancy-post-failure-capacity-analysis/69e035423dbe3f32b95ea93c)

### [The Engineering Math Behind Data Center Cooling Redundancy: Post-Failure Capacity Analysis](https://calcengineer.hashnode.dev/the-engineering-math-behind-data-center-cooling-redundancy-post-failure-capacity-analysis?utm_source=hashnode&utm_medium=feed)

A 2MW data center with 8×350kW CRAC units can lose 25% of its cooling capacity in a single failure, yet still maintain full cooling load—if the math checks out. The Formula At its core, the redundancy calculation follows a logical sequence that mirro...

3 min read · [calcengineer.hashnode.dev](https://calcengineer.hashnode.dev/the-engineering-math-behind-data-center-cooling-redundancy-post-failure-capacity-analysis?utm_source=hashnode&utm_medium=feed)

[Evgenii Konkin](https://hashnode.com/@evgeniikonkin) · [Apr 15](https://hashnode.com/posts/the-engineering-math-behind-crac-unit-sizing-load-summation-and-margin-analysis-for-data-center-cooling/69df8cd1c798ae8a268397df)

### [The Engineering Math Behind CRAC Unit Sizing: Load Summation and Margin Analysis for Data Center Cooling](https://calcengineer.hashnode.dev/the-engineering-math-behind-crac-unit-sizing-load-summation-and-margin-analysis-for-data-center-cooling?utm_source=hashnode&utm_medium=feed)

A typical 42U server rack with 10kW IT load generates enough heat to warm a 1,500 square foot home in winter—yet many engineers treat cooling calculations as simple IT power multiplication. The reality requires summing multiple heat sources with prec...

4 min read · [calcengineer.hashnode.dev](https://calcengineer.hashnode.dev/the-engineering-math-behind-crac-unit-sizing-load-summation-and-margin-analysis-for-data-center-cooling?utm_source=hashnode&utm_medium=feed)

[Pammi Soni | 360iResearch™](https://hashnode.com/@pammi360) · [Jul 11, 2025](https://hashnode.com/posts/adoption-of-brushless-dc-rack-mount-fans-for-improved-energy-efficiency-in-data-centers/687095200fc9cbb8e3487b74)

### [Adoption of Brushless DC Rack Mount Fans for Improved Energy Efficiency in Data Centers](https://pammi360.hashnode.dev/adoption-of-brushless-dc-rack-mount-fans-for-improved-energy-efficiency-in-data-centers?utm_source=hashnode&utm_medium=feed)

In the rapidly evolving landscape of data centers, efficiency and sustainability have become pivotal priorities. As data centers continue to expand to accommodate escalating demands for cloud computing, artificial intelligence, and big data processin...

5 min read · [pammi360.hashnode.dev](https://pammi360.hashnode.dev/adoption-of-brushless-dc-rack-mount-fans-for-improved-energy-efficiency-in-data-centers?utm_source=hashnode&utm_medium=feed)